1. Product Introduction
2. Performance Characteristics
1. Meet the safety and technical requirements of fixed spore traps in the GB/T 24689.3-2009 (Plant Protection Machinery Spore Traps) standard.
2. 15 inch ultra large high-definition capacitive touch screen, Windows operating system, with good human-computer interaction interface.
3. A 1000 magnification microscopic imaging system with 12 million pixels can automatically perform high-definition microscopic photography of captured bacterial spores, and the captured image clarity can meet the requirements of manual identification of bacterial spore types.
4. Automatic spore capture, automatic photography, 24-hour uninterrupted capture of bacterial spores. After constant temperature cultivation of the captured bacterial spores, automatic photography is performed to automatically select the optimal image.
5. It can achieve automated operation throughout the entire process of loading glass slides, capturing bacterial spores, constant temperature cultivation, microscopic imaging, and recycling used glass slides.
6. It has remote and on-site programming functions, and various functions of the device can be set, modified, and read remotely through the network. The working mode is adjustable.
7. The built-in GPS positioning function allows you to view the current device parameters on the map.
8. Time sharing work: The working hours can be set based on the activity habits of target pathogen spores. It can have rain control function and adjust the working status of the equipment according to weather conditions.
9. It can output device operation status information to facilitate remote monitoring of device operation status by the central platform.
10. It is possible to remotely configure device management information such as device switches, working time periods, image capture frequency, and upload image frequency.
3. Technical Parameter
1. Material: GB32080-92 stainless steel
2. Data transmission method: 4G network/5G network (optional), wired network
3. Image collection method: remote network platform manually controls collection, and device timing automatic collection
4. Constant temperature cultivation: temperature control accuracy ± 1 ℃, constant temperature setting range 20-35 ℃, difference between ambient temperature and set constant temperature ≤ 30 ℃
5. Power supply voltage: AC 220V ± 5%
6. Power: ≤ 180W
7. Setting range: timed start, can be set to any 24-hour start time
8. Slide: 365 slides can be added at a time and can be used for 365 days, one slide per day
9. Air speed at the gas gathering port: 0.3~5 m/s
10. Specification of glass slide: length: 76.2mm; Width: 25.4mm; Thickness: 1-1.2mm
11. Insulation resistance: ≥ 2.5M Ω
12. Design life: 5 years
13. Working environment temperature: -20 ° C~70 ° C